This topic describes AID formats that may appear in the alarm Location field for Optical LAN OLTs.  An AID or Access Identifier is the unique name of a port, component or resource within the System. The Table below describes the AID formats and related system components, listed in alphabetical order by AID.

AID Formats - OLT Components

 

AID COMPONENT DESCRIPTION
COAXx-y-z-w-s Tellabs ONT RF video port x = MDS shelf (1)
y = MDS slot (1-16)
z = QOIU port (1-4)
w = ONT (1-32)
s = ONT RF video port (1)
COM OLT connection to EMS OLT unavailable
Note: COM (communication) is used to indicate the "system" in general, since the fault cannot be isolated to a single unit. In the case of a loss of EMS to OLT communication, it could be the facility (GbE), the IP network, or the ESU. As a result, the fault is attributed to COM.
CSx-y-z-w-s Tellabs ONT voice lsubscriber line x = MDS shelf (1)
y = MDS slot (1-16)
z = QOIU port (1-4)
w = ONT (1-32)
s = ONT voice pair (1-2)
ETHx-y-z-w-s Tellabs ONT Ethernet Port x = MDS shelf (1)
y = MDS slot (1-16)
z = QOIU port (1-4)
w = ONT (1-32)
s = Port (1)
ETHx-y-z-w-s-Vc Tellabs ONT Ethernet line x = MDS shelf (1)
y = MDS slot (1-16)
z = QOIU port (1-4)
w = ONT (1-32)
s = Port (1)
c = Subscriber VLAN
MDS1 Tellabs 1134/OLT1 Shelf x= MDS shelf (1) 
MDSx-EFA EFA in Tellabs 1134 NE x = Shelf (1), The External Fan Assembly for the 1134
MDS1-FANx Fan in BOLT OLT x = Fan 1..5
MDSx-ESUy
 
ESU in MDS x = MDS shelf (always 1)
y = A or B (ESU slot)
ESU in Tellabs 1134/OLT1/BOLT x = MDS shelf (1)
y = A  

Note: Only one ESU in Tellabs 1131, there is no ESUB slot.
MDSx-ESUy-IOz ESU downlinks on MDS backplane (to I/O cards, TDU, or AMU) x = MDS shelf (1)
y = A or B (slot)
z = I/O slots (1-16), TDU slots (17-18), or AMU slot (19)
MDSx-ESUy-IOz-IO Uplinks on MDS backplane (to ESU) x = MDS shelf (1)
y = A or B (slot)
z = I/O slots (1-16), TDU slots (17-18), or AMU slot (19)
MDSx-IOx I/O cards x = MDS shelf (1)
MDSx-IOy I/O cards, TDU, or AMU (in MDS) x = MDS shelf (1)
y = I/O slots (1-16), TDU slots (17-18), or AMU slot (19)    

Note: For Tellabs 1134, I/O slot numbers are 1-4.
MDSx-y-z MDS optical downlink to a remote shelf or Tellabs ONT (OLT end) x = MDS shelf (1)
y = MDS slot (1-16)
z = QOIU port (1-4)
MDSx-y-z-w Tellabs 1150 ONT x = MDS shelf (1)
y = MDS slot (1-16)
z = QOIU port (1-4)
w = ONT number (1-32)
MDSx-y-z-w-ONT
 
ONT uplink
 
x = MDS shelf (1)
y = MDS slot (1-16)
z = QOIU port (1-4)
w = ONT number (1-32)
MISC-x Environmental alarm x = Alarm input; Tellabs 1134 (1-8), Tellabs 1150 OLT (1-16 or 1-14)
N1-NVxxxx-BB1-y Ethernet (TLS) cross- connection endpoint on ESU30 SFP port xxxx = Network VLAN ID number y = SFP port (5-6)     

Note: Each network VLAN ID must be unique for connections that support TLS services.