Use the following procedure to Create an Equipment Selector template:

|
Option |
Description |
|
Selector Name |
Specify a name for this selector, Allowable characters include up to 32 alpha-numeric characters, the underscore (_), and/or hyphen(-). This is a required field. |
|
AID Range |
|
|
ONT Type |
Select the ONT Type for this selector. Default is ANY. Select from ANY, ONT120C and ONT120W, ONT702, ONT703, ONT704/714, ONT705, ONT709, ONT728, ONT729, ONT729GP and ONT140C and ONT140W. Note: If a specific ONT is selected, only that ONT Type is affected by the selector. |
|
AID Type |
Select from Shelf, Slot, PON, ONT, Port, default is Shelf. This sets the granularity of the following options. |
|
I/O Slot |
If AID Type is set to Shelf, enter the input/output (I/O) slot this selector is to be applied. The range is 1-16. Note 1: Entering an asterisk (*) indicates any I/O Slot on the shelf. Note 2: If the slot number entered exceeds the number of slots on the shelf, i.e., if set to 16 and this selector is applied to a Tellabs 1134 OLT, the selector is never used. |
|
PON |
If AID Type is set to Shelf or Slot, enter the PON port this selector is to be applied. Range is 1-4 (QOIU7). Note: Entering an asterisk (*) indicates any PON on the card in the selected I/O Slot. |
| ONT |
If the AID Type is set to Shelf, Slot, or PON, enter the ONT this selector is to be applied. Range is 1-32. Note: Entering an asterisk (*) indicates any ONT on the PON. |
| Port |
If the AID Type is set to Shelf, Slot, PON, or ONT, enter the Ethernet port that this selector is to be applied. Range is 1-24. Note 1: Entering an asterisk (*) indicates any Port on the ONT. Note 2: If the port number entered exceeds the actual number of ports of the physical ONT, (i.e., if set to 24 and ANT Type is ONT709), the selector is never used. |
| Number of Equipment |
Enter the number of pieces of equipment this selector is to be applied. The entered number represents which piece(s) of equipment of the last non-blank entry of I/O Slot, PON, ONT, or Port. If the last non-blank entry is 4 and the Number of Equipment is set to 6, this selector is applied to 4 through 10, the last non-blank entry plus the Number of Equipment value. Examples: • AID Type is Shelf, I/O Slot = 4, and Number of Equipment = 4 Selector is applied to any ONT Port, on any ONT, on any PON, of the I/O cards in I/O Slots 4 through 8, on the shelf. • AID Type is Shelf, I/O Slot = 4, PON = 2, Number of Equipment = 2 Selector is applied to any ONT Port, on any ONT, on PON ports 2 and 3, of the the I/O card in slot 4. • AID Type is Shelf, I/O Slot = *, PON = 2, ONT = 16, Number of Equipment = 16 Selector is applied to ONTs 16 through 32, on PON port 2, of any installed I/O card. AID Type is Shelf, I/O Slot = 1, PON = 2, ONT = 16, Port = 3, Number of Equipment = 2 Selector is applied to ONT ports 3 and 4, on ONT 16, on PON port 2, of the I/O card in slot 1. |
| First AID |
Displays the first AID affected by the AID Type, I/O Slot, PON, ONT, and Port selections. Note: An asterisk (*) indicates any I/O Slot, PON, ONT, and/or Port was selected above. |
When all fields are filled in, click the Apply button.
.