Edit
Edit the parameters of a specific ONT.
| Note: * = required parameter |
- Command Path - ont>edit
- Command - Edit
- Object -
- * ont-id= - specifies the location of one or more ONTs
- MDS slot]-[PON port]-[ONT ID] (x-y-z)
-
admin= - controls operation of this ont
- enabled | disabled
- audible-ALeRT (alrt)= - set administrativ state for audible alert on the ont, used for locating the ONT.
- admin - enabled | disabled
- DiffServ-CodePoint (dscp) - apply DiffServ-CodePoint
- profile= - DSCP_Downstream-tmp|DSCP_Upstream-tmp|G-ONT_QoS_DSCP-Down|G-ONT_QoS_DSCP-Up|GW-16DSCP|GW-JITC-QoS|GW-QoS-DSCP-Down|SJ-DSCP|default|tsw_dscp
- Led-Hold-Time (lht)= - LED hold time in seconds
-
Power-Over-Ethernet (poe) - select PoE related parameters
- alarm-admin - controlling PoE alarm reporting (ARC)
- All the listed edits
- external-power= - represents power available
- Watts 0-1000
- threshold= - usage threshold after which lower priority services are powered down
- % 1-99
- alarm-admin - controlling PoE alarm reporting (ARC)
-
Serial-Number (sn)= - serial number expected fir ONT
-
4 letters followed by 8 integers. ex: TSLS00000001
-
-
type= - type of ONT to create
- 120|121w|121wx|131w|140|140cl|142r|180|202|205|248|248X|702|703|704|705gr|709|709gp|712|714g|728gp|729|729gp|742g
- user-LABEL (label)= - User defined label for the ONT
-
any alpha-numeric name
-
- * ont-id= - specifies the location of one or more ONTs
- From the ESUx> command line, input ont edit pon-id=1.4.1 sn=TSLS01234568, and press Enter. Output similar to the following is displayed:
ESUx> ont edit pon-id=1.4.1 sn=TSLS01234568 <enter>
Edit ONT succeeded. ESUx> _
FEEDBACK: Are you happy with this material?
Thank you Your feedback helps us to continually improve our content.