Loader

Edit

Any environmental alarm profile (including the default profiles) can be edited; however, only one profile can be edited at a time. When editing a profile, updates are automatically pushed to all ONTs that are using the edited profile. The following internal actions are performed by Panorama PON:

  • The edited profile is saved to the server database and generates an internal list of all ONTs using the profile.
  • The profile updates are then pushed downstream and changes are applied to each ONTs using the profile.

The following environmental alarm profile attributes can be edited:

  • Description
  • Condition Type
  • Severity
     
    Warning

    Caution: This procedure is momentarily service-affecting all connections associated with the profile. The profile change causes a re-synchronization of the connection.    

Use the following procedure to edit an Environmental Alarm profile:

  1. Select the Profile Name from the Profile/Template List to edit and click the Edit a New Profile () icon in the Main Menu bar or right-click the profile name and use the pop-up menu to select Edit. The Edit Enviromental Alarm Profile dialog is displayed.


     
  2. In the Edit Enviromental Alarm Profile dialog, refer to the Environmental Alarm Profile Attributes table and fill in the fields as desired to edit the alarm profile.
  3. When all the fields have been edited, click on the Apply button.
  4. Panorama PON displays the Environmental Alarm Profile Edit Status dialog.


     
  5. If it is necessary to perform other client activities, the Environmental Alarm Profile Edit Status
    dialog can be moved or closed. The process continues in the background.


     
  6. To open and monitor the Environmental Alarm Profile Edit Status dialog again, click the View Edit Status () icon in the toolbar.
    If the process has finished with no errors, EMS displays the message Profile Edit is not in progress. If this happens, click on the Ok button.
  7. If errors occur, the exceptions are listed in the Error Status section. Perform one of the following actions:
    • Click on the Retry button to update these NEs again.
    • Click on the Terminate button to abort the process with errors.
      Information Note: Typically, these OLT errors are caused by a loss of communication between the EMS server and the OLT.
  8. When terminating the process with errors, a warning message confirms that the process was aborted. In the dialog that appears, click on the Ok button.
  9.  When finished, click on the Close button.
  10. Click on the Close button again to close the Profile Tool.