Use the following procedure to change an environmental alarm profile assignment:

  1. Logon to EMS and in the Network common tree, right-click on the target OLT and select Properties from the dropdown list.

  2. In the ONT property dialog, click the Env Alarm tab. 
Information Note: When assigning an alarm profile to a Tellabs 1134/OLT6, the Env Alarm tab displays the first eight (8) alarm contacts in the profile (the ESU30 supports eight (8) alarm contacts only). If any additional contacts are defined in the profile, they are not applied to the Tellabs 1134.
  1. The Environmental Alarm list is displayed.
     


 

  1. In the Profile Name field, click the drop-down arrow and select the environmental alarm profile to be assigned to this NE.
     

  1. Select the Alarm Contact number and click the Alarm Reporting field. In the drop-down select Active or Inactive.
    Information Note: When necessary, click the Activate All or Deactivate All buttons to apply the same changes to all contacts.
  2. After activating the required alarms, click on the Apply button. 
  3. EMS applies the profile and displays a confirmation message. Click on the OK button to continue.
  4. Click on the Close button to finish the Access Alarms session.