Loader

List Current Alarms

 

 

To verify the alarm and location (terminal/shelf/slot).

  1. Log on to the Panorama POM EMS.
  2. Select the Alarms  icon in the Application window, select the OLT in the Common Tree, and select the Current Alarms button in the Main window.


     

From Command Line Interface (CLI)

Use the List Current Alarms command to list the location of all uncleared alarms in the Tellabs 1000 MSAP system for the location range and alarm severity selected.

To find the List Current Alarms command, follow this path:

  1. On the Main Menu screen select 2. Maintenance Menu and press Enter.
     
    Main Menu
      1. Provisioning Menu
      2. Maintenance Menu <Enter>
      3. Testing Menu
      4. Traffic Menu
      5. Administration Menu
      6. Log Off
      A. All Current Alarms
      ?. Help
  2. On the Maintenance Menu screen select 1. Alarm Operations Menu and press Enter.
     
    Maintenance Menu
     1. Alarm Operations Menu <Enter>
     2. List TR-8 Group Status
     3. Performance Monitoring Menu
     4. List Digital Line Card Status
     5. Manual Protection Switch
     6. Manual Software Activation
     7. List Uncalibrated Equipment
     8. List ADSL Bits per Tone
     9. List Protection Group Status
     10. List ADSL Gains per Tone
     A. All Current Alarms
     B. Main Menu
     *. Main Menu
     ?. Help
  3. On the Maintenance Menu screen select 1. List Current Alarms and press Enter.
     
    Alarm Operations Menu
     1. List Current Alarms <enter>
     2. Modify Alarm Settings
     3. List Alarm History
     4. Clear Alarm History
     5. Operate Alarm Cut Off
     6. Operate Extended Alarm Cut Off
     7. Modify ACO Configuration
     8. Alarm Suppression
     9. Modify Audible Alarm Configuration
     10. Delete Equipment
     A. All Current Alarms
     B. Maintenance Menu
     *. Main Menu
     ?. Help

From the List Current Alarms command, do the following:

Information Note: Input ? and press Enter to see valid options for any field.
  1. On the command line input Starting Plug-In Location [LET-1-1]. Press Enter to continue.
  2. On the command line input Ending Plug-In Location [RST2-8-PSUB]. Press Enter to continue. 
  3. On the command line input Alarm Severity [All].  Press Enter to continue.
  4. Alarms for the inputted location and this severity level and greater will display.
    Enter Starting Plug-In Location [LET-1-1]: LET-1-1 <Return>
    Enter Ending Plug-In Location [RST2-8-PSUB]: RST2-8-PSUB <Return>
    Enter Alarm Severity [ALL]: All <Return>
    Location    Status Alarm                 Plug-In      Time
    -------------------------------------------------------------------
    RST2        Set MN Link to RST1                       5/07/02 08:14:22
    LET-1-11    Cur MJ LOS                   T1X-XCVR     5/03/02 10:17:45
    LET TR-8 2  Set MN TR-8 Minor NE                      4/27/02 12:50:31
    LET-1-12    Set MJ LOF TR-8 2                         4/27/02 07:44:12
    LET-1-19    Cur CR LOS                   OC3cu-XCVR   4/21/02 08:30:02
    RST1        Cur CR Timing No OCn Support              4/21/02 08:30:02
    LET         Cur CR xDSL Shutdown - Low                4/20/02 09:42:10
    LET-G4-2    Cur MJ APS Prov. Mismatch    OC3-XCVR     4/20/02 10:45:10
    LET-1-18    Cur MJ Not in Prot Group     OC3-XCVR     4/20/02 07:52:10
    LET-2-1     Cur MN Missing Card          DS3          4/20/02 06:39:14
    RST1-2-18   Cur MJ AIS                   T1HD4-AD     4/20/02 10:52:10
    RST1-1-15   Cur MN Missing Card          HD R-POTS    4/19/02 07:55:11
    RST1-3-1    Cur MN Missing Card          ADSL 24+x    4/11/02 04:39:10
    RST1-2-17   Cur MN Missing Card          ADSL2+ 6+x   4/10/02 10:54:13
    Current Alarms Listed: 3 CR, 5 MJ, 6 MN, 0 ST

     


 


 


 


 