ONT Configuration

Use the following procedure to view or edit the ONT Configuration.

  1. In the ONT Property dialog, the Configuration tab is displayed by default.

  2. On the Configuration tab, the User Label field can be provisioned, as described in the Table below:
     

    Field

    Description

    User Label

    User-assigned label. Note that the user label can be set only if the ONT is provisioned and the serial number is set.

    The User label contents are displayed in the Common Tree.

    Slot

    The ONT position on the OLT PON port. Range is 1 to 32.

    Configured Card

    The ONT type provisioned in this position.

    CLEI Code

    The Common Language code set (combined numerics and mnemonics) used to locate, inventory and manage aspects of network components. CLEI code of the ONT.

    System Version

    The active Optical Line Terminal (OLT) software version.

    Software Details

    The active and standby software versions currently uploaded to the Ethernet Switch Unit (ESU) and ONT.

    Manufacturing Date

    The manufacturing date of the ONT.

    Status & Statistics

    Equipped Card

    The actual equipped card type.

    Alarm Status

    Current alarm status of the ONT.

    Operational Status

    Current operational status of the ONT [Enabled / Disabled]