ONT Power Consumption

Tellabs ONT Power Consumption

Name

Qty

Unit Power
(Watts)

Ext Power
(Watts)

BTU/hour

Measured
(Watts)

Volts

Amps

Inrush Amps

120W/C ONT (No PoE)

1

6.7

6.7

23

 

     

120W/C ONT (Full PoE)

1

22.1

22.1

75

 

     

704G

1

8.7

8.7

30

 

     

705GR

1

14.4

14.4

49

 

     

709G

1

7.5

7.5

26

 

     

709GP (No PoE)

1

7.5

7.5

26

 

     

709GP (Full PoE)

1

70

70

 239

 

     

140W (No PoE)

1

7.5

7.5

26

3.78

     

140W (Full PoE)

1

70

70

239

65.34

50

1.4

10

140C (No PoE)

1

7.5

7.5

26

4.32

     

140C (Full PoE)

1

70

70

239

65.34

50

1.4

10

180C (No PoE)

1

7.5

7.5

26

7.5

     

180C (Full PoE) Rev A to D

1

140

140

478

150

50

2.8

 

180C (Full PoE) Rev E on

1

320

320

1,092

150

50

6.4

 

142R  (No PoE)

1

7.5

7.5

26

4.32

     

142R (Full PoE)

1

70

70

239

63.72

50

1.4

 

728/9GP (No PoE)

1

45

45

154

 

     

728/9GP (Full PoE)

1

550

550

1,878

 

     

131W (No PoE)

1

7.6

7.6

26

 

     

131W (Full PoE)

1

30

30

102

 

     

SFP ONT

1

1.485

1.485

5

 

3.3

0.45

0.45

  • 729GP POTS only

1

 

 

 

       
  • 729GP Ethernet only

1

62.6

 

 

       
  • 729GP Ethernet and POTs

1

140

 

 

       
  • 729GP Ethernet (full POE)
    and POTs

1

588

 

 

       

248 (No PoE) Full traffic

1

71

71

242

 

50

1.42

 

248 (Full PoE)

1

635/1350

635/1350

 2168/4609

 

50

 

The power

supply

determines

the

maximum

202 (No PoE)

1

7.5

7.5

26

 

50

0.15

 

202 (Full PoE)

1

120

120

410

 

50

2.4

 

205 (Full PoE)

1

140

140

478

 

50

2.8

 

203W (Full PoE)

1

70

70

239

 

50

1.40

 

224 (No PoE) Full traffic

1

41

41

140

 

50

0.82

 

224 (Full PoE)

1

1481

1481

5,056

 

50

29.6

2 Non

Redundant

1100W

supplies