ONT Status
ONT attributes vary somewhat by ONT type. The ONT has the following status attributes:

ONT Status Attributes
| Attribute | Value | Description |
| Aid | MDS1-1-<pon>-<ont id> | AID or Access Identifier used to identify the ONT. For BOLT, the shelf and slot are always one and so always have a leading MDS1-1 at the beginning of the AID.. |
| Installed-type |
ont070 | 120 | ont121-w | ont121-wx | ont131-w | ont140 | ont140-cl | ont142-r | ont180 | ont202 | ont203-w | ont205 | ont224 | ont248 | ont248-x | ont701 | ont703 | ont704 | ont705 | ont709 | ont712 | ont729 | ont729-gp | ont734 | ont742-g | ont742-gr | ontbasic |
Provides a list of types |
| Alarm-state |
None |
Alarm state is invalid or unknown This alarm is a warning, not service affecting. Minor, this alarm affects only a single entity / user. Major Affects 96 users or less, service affecting Affects 96 users or more, service affecting. |
| Cp-state | Container | |
| Cp-state | Unknown = 0 slave =1 master = 2 not-ready 3 normal 4 |
The current state of this circuit pack. |
| Cp-info | string | String describing the current state of the circuit pack. |
| Info | Container (list) | |
| Index | 1..n | The index of the info. |
| Oper-state | Up or down | The operational state of the port. |
| Availability-state | e-notsupported e-intest e-failed e-poweroff e-offline e-offduty e-dependency e-degraded e-notinstalled e-logfull eunauthaccess |
Further description of failure. Availability state reportin not supported Test currently in progress on entity Failed due to equipment or port problem Device is powered off Device has been administered down Scheduled device is not active now Depend on device that is currently down Operational but service impacted Equipment is missing to render service Stopped due to log being full Down due to authentication failure. |
| Inventory | container | |
| Sw-info | container | |
| Active-image | container | |
| Build-date | String | The date when the software load was built. |
| Version | String | The version number of the software. |
| Build-id | String | The unique number given to each build. |
| System-version | String | The system version this software is a part of. |
| Stand-by-image | container | |
| Build-date | String | The date when the software load was built. |
| Version | String | The version number of the software. |
| Build-id | String | The unique number given to each build. |
| System-version | String | The system version this software is a part of. |
| Hw-info | Container | |
| Model-revision | String | The revision number of the hardware. |
| Inventory-format | ||
| Manufacture-date | String | The date when the hardware was bult. |
| Clei-code | String | For telco devices, the common language equipment identifier. |
| Serial-number | String | The serial number of the card, olt or ont. |
| Supported-Card-group-type | ont070 | 120 | ont121-w | ont121-wx | ont131-w | ont140 | ont140-cl | ont142-r | ont180 | ont202 | ont203-w | ont205 | ont224 | ont248 | ont248-x | ont701 | ont703 | ont704 | ont705 | ont709 | ont712 | ont729 | ont729-gp | ont734 | ont742-g | ont742-gr | ontbasic | The type of hardware. |
- Command Path – show>tolt>ont>
- Action – show
- Module – tolt
- Container – ont
- Status Attributes – .
- AID – AID or Access Identifier used to identify the ONT. For BOLT, the shelf and slot are always one and so always have a leading MDS1-1 at the beginning of the AID..
- MDS1-1-<pon>-<ont id
- Installed-type – Provides a list of types.
- ont070 | 120 | ont121-w | ont121-wx | ont131-w | ont140 | ont140-cl | ont142-r | ont180 | ont202 | ont203-w | ont205 | ont224 | ont248 | ont248-x | ont701 | ont703 | ont704 | ont705 | ont709 | ont712 | ont729 | ont729-gp | ont734 | ont742-g | ont742-gr | ontbasic
- Alarm-state – Alarm state is invalid or unknown
This alarm is a warning, not service affecting.
Minor, this alarm affects only a single entity / user.
Major Affects 96 users or less, service affecting
Affects 96 users or more, service affecting.-
None | Warning | Minor | Major | Critical
-
-
Cp-state – Container
- Cp-state – The current state of this circuit pack..
- Unknown = 0
slave =1
master = 2
not-ready 3
normal 4
- Unknown = 0
- Cp-info – String describing the current state of the circuit pack.
- String
- Cp-state – The current state of this circuit pack..
-
info – Container
- Index – The index of the info.
- 1..n
- Oper-state – The operational state of the port.
- Up or down
- Availabilty-state – Further description of failure.
Availability state reportin not supported
Test currently in progress on entity
Failed due to equipment or port problem
Device is powered off
Device has been administered down
Scheduled device is not active now
Depend on device that is currently down
Operational but service impacted
Equipment is missing to render service
Stopped due to log being full
Down due to authentication failure- e-notsupported
e-intest
e-failed
e-poweroff
e-offline
e-offduty
e-dependency
e-degraded
e-notinstalled
e-logfull
eunauthaccess
- e-notsupported
- Index – The index of the info.
-
Inventory – Container
- Sw-info – Container
- Active-image – Container
- Build-date – The date when the software load was built.
- Version – The date when the software load was built.
- Build-id – The unique number given to each build.
- System-version – The system version this software is a part of.
- Active-image – Container
- Sw-info – Container
- Stand-by-image – Container
- Build-date –- The date when the software load was built.
- Version – The version number of the software.
- Build-id – The unique number given to each build.
- System-version – The system version this software is a part of.
- Hw-info – Container
- Model-revision–The revision number of the hardware.
- Inventory-format
- Manufacture-date – The date when the hardware was built.
- Clei-code – For telco devices, the common language equipment identifier.
- Serial-number – The serial number of the card, olt or ont.
- Supported-Card-group-type – The type of the hardware.
- ont070 | 120 | ont121-w | ont121-wx | ont131-w | ont140 | ont140-cl | ont142-r | ont180 | ont202 | ont203-w | ont205 | ont224 | ont248 | ont248-x | ont701 | ont703 | ont704 | ont705 | ont709 | ont712 | ont729 | ont729-gp | ont734 | ont742-g | ont742-gr | ontbasic
- AID – AID or Access Identifier used to identify the ONT. For BOLT, the shelf and slot are always one and so always have a leading MDS1-1 at the beginning of the AID..
Show ONT Status Example
- Command Path – Show>tolt>ont>
- Action – show
- Module – tolt
- Types – Example Parameters
- | tab
- From the MDS1-ESUA<Config># command line, input show tolt ont | tab, and press Enter.
- Outputs similar to the following are displayed:
MDS1-ESUA<Config># show tolt ont | tab <enter>
INSTALLED ALARM CP CP OP AVAILABILITY BUILD BUILD SYSTEM BUILD BUILD SYSTEM MODEL INVENTORY MANUFACTURE CLEI SERIAL CONFIGURED
AID TYPE STATE STATE INFO INDEX STATE STATE DATE VERSION ID VERSION DATE VERSION ID VERSION REVISION FORMAT DATE CODE NUMBER TYPE
-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
MDS1-1-1-1 e-unknown e-cleared 4 0 down [ e-failed ] n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a ont248
MDS1-1-1-2 e-unknown e-cleared 4 0 down [ e-failed ] n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a ont205
MDS1-1-1-3 e-unknown e-cleared 4 0 down [ e-failed ] n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a ont248-x
MDS1-1-1-4 e-unknown e-cleared 4 0 down [ e-failed ] n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a ont202
MDS1-1-1-5 e-unknown e-cleared 4 0 down [ e-failed ] n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a ont203-w
MDS1-1-2-1 e-unknown e-cleared 4 0 down [ e-failed ] n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a ont140
MDS1-ESUA<Config># _
|