Replace the AC-DC Rectifier
This section provides basic instructions for removing and replacing an inoperable AC - DC rectifier from the Tellabs OLT1.
Figure 1: AC-DC Rectifier

Use the following procedure to replace the AC-DC rectifier.
Remove the AC-DC Rectifier
If the rectifier Fault light displays RED, it indicates the rectifier is inoperable.
Figure 2: Fault Light Displays
The rectifier should be shipped back to Tellabs® and a new rectifier will be sent to the customer’s site as a replacement. Follow the procedures below to remove the rectifier:
| Note: The customer will purchase a new rectifier from Tellabs®. Contact the Tellabs Technical Assistance Center (TAC), for instructions. |
- If the OLT1unit is already rack mounted, slide the unit forward a couple of inches or remove it from the rack to gain access to the faceplate screws.
- Locate the rectifier cover plate on the OLT1.
- Using a Phillips screwdriver, remove the 4 screws (two on top and two on bottom) of the rectifier cover plate.
- Remove the rectifier cover plate.
- Loosen the right and left screws that hold the rectifier retractable handles in position.
Figure 3: Retractable Handles

6. Remove the rectifier from the slot.
7. If the rectifier is not going to be shipped back to Tellabs, dispose of the rectifier ac- cording to local practices or regulations.
Install the AC-DC Rectifier
When the customer receives a replacement rectifier, follow these procedures to install the new rectifier into the Tellabs OLT1.
- Locate the package containing the rectifier.
- Examine the package for any apparent damage. If damage is noted, contact Tellabs Technical Assistance Center for assistance and additional instructions.
- If no damage is noted, open the package and examine the rectifier for any apparent damage.
- If damage is noted, contact Tellabs Technical Assistance Center for assistance and additional instructions. Refer to Contacting Technical Support.
- If no damage is noted, remove the rectifier from the packaging.
- Pull both handles out to approximately 45 degrees, as shown in Figure 4, ready for installation.
Figure 4: Handle Positioning

| Note: This may require the slackening and disengaging of the right and left screws that hold the handle in position. |
- Locate the rectifier into the slot and actively push it all the way to the back until the power module connector and the locking mechanism engage.
- Observe the following rectifier activity.
Figure 5: Rectifier Initializing

- Power LED illuminates GREEN as the unit is initializing.
- Fan starts up.

Note: The fan should turn counterclockwise, and air is pulled into the rectifier.
- When the rectifier has stabilized, in approximately 8 seconds, push the retractable handles in so that they are flush with the power module faceplate. This will fully engage and lock the power module into place.
- Using the Phillips screwdriver, tighten the two screws (one on each side) to hold the handles in the locked position.
- Locate the rectifier cover plate on the left side of the OLT1 faceplate.
- Replace the rectifier cover plate.
- Tighten the two screws on the top and the bottom of the rectifier cover plate.