Loader

SFP Status

  • Command - sfpinfo
  1. From the  ESUx>  command line, input sfpinfo, and press Enter. Information similar to the following is displayed for up to six Uplinks:
    ESUx> sfpinfo <enter>
    
                Uplink1          Uplink2          Uplink3          Uplink4
                ================ ================ ================ ================
    Admin     : Enabled          Enabled          Enabled          Disabled
    Oper      : Up               Down             Down             Down
    Vendor    : FINISAR CORP.
    P/N       : FCMJ-8521-3
    Rev       : 4
    S/N       : P8C2520
    Date Code : 050918
    Wavelength: 0     nm         -1    nm         -1    nm         -1    nm
    Temp      : Unsupported      Unsupported      Unsupported      Unsupported
    Voltage   : Unsupported      Unsupported      Unsupported      Unsupported
    Tx Current: Unsupported      Unsupported      Unsupported      Unsupported
    Tx Opt Pwr: Unsupported      Unsupported      Unsupported      Unsupported
    Rx Opt Pwr: Unsupported      Unsupported      Unsupported      Unsupported
    Avl States: ---              NOTINSTALLED     NOTINSTALLED     NOTINSTALLED
    Alarm Stat: No Alarm         Low Sig          Low Sig          Low Sig
    ESUx> _