Loader

Site Preparation

Installation of the BOLT OLT will require the following tools:

  • Power Wiring: If using DC wiring, 16 to 18 AWG wiring is recommended. 
  • Laptop Computer: A laptop computer is only required if the network is not set up for ZTP.  This laptop would be used for manual turnup of the BOLT OLT and proper configuration of the uplink interfaces.
  • Uplink Lasers: Ensure you have purchased the appropriate Tellabs supported Modules shown in the "OLT Laser Part Numbers" table shown below.

OLT Part Numbers

  Part Number   Description   Comments
81.11S-BOLT FlexSYM BOLT OLT 16 PON Equipped with fans
81.11A-FA1RU12V Fan Module for 1RU Chassis Replacement fans
81.11P-PW715W FlexSYM 715W Power Supply C13 Cord Required
81.11W-C13TYPB-3 PWR AC Cord C13 to Type B US 3 FT For 715W Power Supply
81.11P-PW1100W FlexSYM 1100W Power Supply C15 Cord Required. 
81.11W-C15TYPB PWR AC Cord C15 to Type B US 7.5 FT For 1100W Power Supply

Laser Part Numbers

Laser modules for the PONs and Uplinks must be purchased separately. The BOLT OLT comes equipped with no laser modules.

OLT Laser Part
Number

Laser Description Distance Connector Comments
0410-0471 850nm 10G SR SFP+ 400m MMF 2xLC Short Range MMF 10G Laser
0410-0470 1310nm 10G LR SFP+ 10km SMF 2xLC Long Range 10km 10G Laser
81.11T-SFPXGSPON 1270nm/1577nm 10G SFP+ XGSPON <20km SMF SC/UPC XGSPON 10G Laser I-temp
81.11T-QSFPP40GSR4 QSFP+, 40GE Multi-Mode Optical Transceiver, 150m, 850nm, MPO12, C-Temp 150m MMF MPO12 Short Range 40G Laser
81.11T-QSFP28100GSR4 QSFP28, 100GE Multi Mode Optical Transceiver 100m, 850nm, MPO12, C-Temp 100m MMF MPO12 Short Range 100G Laser
81.11T-QSFPP40GLR4 QSFP+, 40GE Single Mode dual fiber transceiver, 10km, 1310nm, Duplex LC, C-temp 10km 2xLC Long Range 40G Laser
81.11T-QSFP28100GLR4 QSFP28 100GE Single Mode Optical Transceiver 10km, 1310nm, Dual LC, C-temp 10km 2xLC Long Range 100G Laser

Power Requirements

The BOLT OLT has the following AC power requirements when powered by AC:

  AC Power Specifications   Value
AC Input Voltage 100-240VAC
AC Input Line Frequency 50-60Hz (nominal)
AC Current Rating 2.05 A @ 100VAC, .86 A @ 240VAC
Max AC Input Power 206 W
Max Power for 5 BOLT OLTs 10.17 A @ 100VAC, 4.24 A @ 240VAC

 

The BOLT OLT has the following DC power requirements when powered by DC:

  DC Power Specifications   Value
DC Input Voltage 40-60VDC
DC Current Rating 3.65 A @ 48VDC
DC Power 175 W

 

Additional Power Safety Requirements

  • N/A

Environmental Specifications

Environmental Specifications Value
Dimensions 19 x 16.7 x 1.7 in (483 x 424 x 43 mm)
Certifications UL-62368-1 Pending FCC Pending
Operating Temperature Range 0ºC to +40ºC (32ºF to 104ºF)
Operating Humidity 5% to 95% non condensing

Previous  |  Next