Tellabs 1000 Series OLTs

Refer to the following table to determine which specific modules are required for the shelf being installed. Click on the link in the Procedure column to go directly to the specific procedure. Perform the procedures.

 

Card Description Shelf Procedure
Common Cards
ESU11 Master Ethernet Switch Unit MDS5 or MDS7 "Install Ethernet Switch Unit (ESU11 or ESU2)"
ESU2
ESU11 Provision Ethernet Switch Unit MDS5 or MDS7 "Turn Up and Provision ESU11 or ESU2"
ESU2
ESU11 Redundant Ethernet Switch Unit MDS5 or MDS7 "Install the Redundant ESU11 or ESU2"
ESU2
TDU1 Timing Distribution Unit MDS5 "Install the TDU1"
AMU1 Alarm Maintenance Unit "Install the AMU1"
Input/Output Application-Specific Cards
QOIU7 Quad Optical Interface Unit All "Install a Quad Optical Interface Unit (QOIU7)"

 

Both the MDS5 and MDS7 require an Ethernet Switch Unit (ESU11 or ESU2) that is the shelf controller. Additionally, the MDS5 supports optional redundant Timing Distribution Units (TDU1) and Alarm Maintenance Unit (AMU).

The TDU1 converts the analog composite clock timing signal to a digital timing signal which is then transported across the backplane to the Ethernet Switch Unit (ESU). The digitized timing signal can then be transported, by the ESU, to up to thirty-two (32) Internet Protocol (IP) addresses provisioned in Panorama PON.

The AMU1 provides alarm collection, reporting, and an audible alarm, as well as visual capabilities for the system.